Firmware Revision History

Firmware 2.0.1 (MAR/26/2025) avbtool_2.0.1_v176_20250326.swu
  • Avnu™ MILAN® Certified

  • Feature: (MIDI) Improved response to parameter change request messages

  • Feature: Faster change of sampling rate

  • Fix: 0 dBFS signals immediately following a clipped signal would continue to indicate OVR

  • Feature: Improved user guidance after change of sampling rate while streaming

  • Feature: Faster preset name changes

  • Feature (WebUI/GUI): Better visualization of peak levels when peak levels are activated

  • Feature (WebUI): Improved appearance of truncated labels

  • Feature (WebUI): Change device name using the web interface

  • Fix (WebUI): Firmware update will proceed even if browser connection is lost

  • Feature (WebUI): Show miniature level meters while in routing mode

  • Feature (GUI): Add scales to mic and phones level meter background

Changing sampling rates will change the sampling rate of the device but keep existing AVB streams running with wrong stream format and audio payload due to MILAN requirements. It is highly recommended to use an ATDECC controller (Milan Manager® or Hive) to manage routing and sampling rate changes in MILAN environments.
Firmware 1.7.1 (NOV/01/2023) avbtool_1.7.1_v171_20231101.swu
  • Fix: ATDECC: Closing a controller stopped notifications to other controllers on the network

  • Fix: AVB Redundancy: Destination MAC address was not set correctly while other port active

  • Fix: Update from firmware 1.2.4 or earlier to firmware 2.5.0 failed

Firmware 1.7.0 (JUL/12/2023)
  • Feature: Faster remote control and snappier web remote interface

  • Feature: Faster boot time

  • Feature: AVB: Entity model has been updated (for example: to reflect controls on jacks)

  • further improvements under the hood addressing MILAN compatibility and minor bug Fixes

Firmware 1.6.2 (APR/18/2023)
  • Fix: Some 100 MBit/s devices did not connect properly

Firmware 1.6.0 (JAN/19/2023)
  • Feature: A static IP address can be assigned on the device

  • Feature: A dedicated CRF Stream has been added for MILAN conform AVB clocking

  • Feature: New stream configuration dialog (web ui)

  • Fix: Sync issue when receiving signal from RME MADI Router

  • improved: Error handling in JSON(SSC) API

  • improved: ATDECC Counters and Notifications

  • improved: MILAN compliance

  • additional minor Fixes and improvements

Firmware 1.5.1 (MAY/12/2022)
  • Fix: AutoSet and Phase indicators were not displayed correctly

Firmware 1.5.0 (MAR/22/2022)
  • Fix: MILAN counters

  • Fix: under specific circumstances, the previous 1.4.0 firmware could cause presets to get corrupted

  • improved: MILAN compatibility

  • improved: MIDI over MADI remote control

Firmware 1.4.0 (AUG/22/2021)
  • Feature: IEC 60268-18 scaling for levelmeters

  • Feature: MIDI over MADI control

  • Fix (webUI): presentation time offsets were not correctly displayed after change

  • Fix: routings at single speed had an effect on soundness at double/quad speed

  • improved: display of preset names in webUI and on the device display

  • improved: CRF Stream support

  • improved: MILAN compatibility

Firmware 1.3.0 (DEC/07/2020)
  • Feature: AutoSet Gain

  • Feature (web): peak indicators in level meters

  • Feature (web): support consecutive channel naming with TAB key

  • several additional Fixes and improvements for the web remote

Existing presets will be updated to the new firmware and cannot be used with previous firmware versions. Please back up your existing presets in case there is a need to revert to an earlier firmware.
Firmware 1.2.0 (NOV/04/2020)
  • Feature: upload and download presets

  • Feature: possibility to rename presets

  • Feature: automatic update checks

  • Feature: AVB: media locked counter for input streams

  • Feature: web: direct link to online manual

  • improved: web: font rendering

  • improved: web: error handling (WebGL)

  • Fix: web: memory usage in routing mode

  • Fix: web: several graphics issues

  • and additional minor Fixes and improvements

Firmware 1.1.2 (AUG/18/2020)
  • Feature: web: remote tab shows device name in title

  • improved: auto stream reconnect on format change

  • improved: web: gain setting responsiveness

  • Fix: quick start preset routing for stream 2

  • Fix: web: touch compatibility

  • Fix: web: grid/snap behavior

  • Fix: USB: connection with Mac OS Catalina

Firmware 1.1.1 (MAY/15/2020)
  • improved: performance of web app

  • improved: release time of level meters now adheres to EBU Tech 3205-E

  • improved: routings on the device now require a confirmation

  • improved: web: channel indicators within input ports

  • improved: display while booting the device

  • Fix: MAAP was not working

Firmware 1.1.0 (MAY/8/2020)
  • new: load a quick-start preset by pressing first button next to display while booting (power on until LED pulsing)

  • new: adjust stream size when setting higher sampling rate

  • new: web: line level, phase switches

  • new: improved boot logos with black background

  • new: SSC / JSON API error handling

  • improved: performance of gain pots

  • improved: fine adjust gain by holding shift key

  • improved: soft start of analog voltages after brief power supply interruption

  • improved: visualization of clipping LEDs

  • Fix: AVB stream connections to Digiface are reestablished on boot

  • Fix: phase of analog outputs

  • Fix: gain setting of analog outputs in mono mode

  • Fix: temperature was not shown

  • Fix: web: level meters of AVB stream 8

  • Fix: pass through of incoming MIDI over MADI messages

Firmware 1.0.0
  • initial release

When downgrading to an earlier firmware version, presets and current settings will get lost.