Power State
|
The power tab in the STATE section informs the user which of the two power inlets receive power. Its icon is a realtime representation of the current power state, with an inactive power supply shown in grey. The AC input corresponds to the left icon, the DC input to the right icon. |
Representation of the state of power supplies on the device
-
Open the power tab in the STATE section
-
The state of each power input is shown as active if it receives power.
Representation of the state of power supplies on the web remote
-
Connect the device by USB or network cable and open the Remote Control Overview.
-
A click on the Power icon reveals the current state of the power supplies.
Notification of Single Power Failure
A warning can be displayed when one of two connected power sources fails.
On the display, a warning is signaled as an icon with a red bar:
|
Power loss at secondary PSU |
-
Open the power tab in the STATE section.
-
Toggle the switch Redundancy to On.
-
In the STATE section, activate the toggle next to Power Loss Warning.
The warning signals only the current state. It does not keep a record of past power failures. |