Set Word Clock Output to Single Speed

At sample rates > 48 kHz, it may be necessary to synchronize two devices with a fraction of the actual sample rate:

Sample Rate Word Clock Full Speed (default) Word Clock Single Speed (option)

88.2 kHz

88.2 kHz

44.1 kHz

96 kHz

96 kHz

48 kHz

176.4 kHz

176.4 kHz

44.1 kHz

192 kHz

192 kHz

48 kHz

To set the Word Clock output to single speed on the device:
  1. Open the CLOCK section.

    w162 440 1T 1
  2. Move the cursor onto the toggle switch Word Out Single and push the encoder to change the value.

To set the Word Clock output to single speed on the web remote:
  1. Locate the CLOCK section.

  2. Move the cursor onto the Word Out Single switch and push the encoder to change the value.