Clock Status

The clock of all digital inputs is continuously monitored with SyncCheck™ and shown in the CLOCK section. A warning (red) occurs when the chosen clock source fails. A caution (orange) is displayed when a routed signal is out of sync. A notice (light yellow) is displayed when a signal is present/locked, but not in sync and not routed. A good notice (light green) is displayed when a signal is present and in sync, but not routed or chosen as clock source. A good confirmation (green) is shown when the signal is present and either chosen as source or routed and in sync.

A warning causes the CLOCK section to turn red, and the selected source generating the issue is displayed