Presets

Any change in the device configuration is persistent. After a power loss, the device will revert back to its last state. Additionally, the M-32 DA Pro can save fifteen states in presets numbered 1-15. After a preset is loaded, any change in the configuration will result in an unsaved changes state.

wAL 120 1C 1

Representation of an unsaved preset on the device.

The internal preset storage is not affected when the device firmware is updated to a newer firmware version. Moreover, recalling the factory default preset does not delete any other saved preset.

Settings that are not saved in a Preset

The following settings are not saved in a preset:
  • Auto-lock

  • Lock code

  • Remote control

  • Static IP/DHCP configuration

  • MIDI Remote Control ID

Saving Presets

Up to 15 presets can be saved in the internal storage of the M-32 DA Pro.

To save a preset on the device:
  1. Open the preset tab in the STATE section. The cursor will highlight a preset number.

    Preset Tab in State section
  2. Push and rotate the encoder to choose a preset number.

  3. Push Save to save the preset.

To save a preset using the web remote:
  1. Open the web remote and locate the preset tab.

    wAL 120 2T 2

    wAL co 1

    Status Indicator and tab

    wAL co 2

    Current preset and state

    wAL co 3

    Selected preset

    wAL co 4

    Save preset

  2. Click on a preset name in the left column wAL co 3 to select a preset.

  3. Press the Save button wAL co 4.

Loading Presets

Up to 15 custom presets can be loaded from the internal storage of the M-32 DA Pro.

Loading a preset cannot be undone. Ensure that any important configuration has been saved to another preset before proceeding.
The device name is part of the preset. When a preset is loaded, the device name is changed to the value stored in the preset.
To load a preset on the device:
  1. Open the preset tab in the STATE section (see: Use of the Display and Encoder).

    w32 120 3T 1
  2. Move the cursor to the current preset number and push the encoder.

  3. Rotate the encoder to choose a preset, and confirm by pushing the encoder.

  4. Select Load to load the preset.

To load a preset using the web remote:
  1. Locate the preset tab

    wAL 120 3T 2

    wAL co 1

    Status Indicator

    wAL co 2

    Current preset and state

    wAL co 3

    Load (or Revert) button

  2. Use the drop-down menu wAL co 3 to select a preset.

  3. Press the Load Button wAL co 4.

Loading Factory Default Settings

The factory default settings are saved internally as Factory Preset and cannot be overwritten.

To load the factory defaults, load the 16th preset labelled Factory Preset.

Loading the factory defaults does not delete any saved presets. It also does not affect the lock settings in the STATE section.