Routing Signals to the Outputs

Each output channel of the M-1620 Pro D can receive any input signal. The factory default preset does not contain any routing.

A routing immediately activates input monitoring for a corresponding digital input and raises a warning in the input state if the source signal is not available or out of sync.

The following example shows the procedure to route to MADI Coaxial output channels. Other outputs follow the same procedure.

To create a routing to a MADI output on the device:
  1. Open the OUTPUT section.

    Coaxial Output
  2. Rotate the encoder to highlight the coaxial or optical MADI icon.
    "Route Signals to MADI Coaxial/Optical Output" text will be shown on the display.

  3. Press the encoder to open the routing. The cursor will highlight the first available channel block.

  4. Either rotate the encoder to select the next available channel block or press it to start assigning the source signal.

  5. Again, rotate the encoder to select the source for the selected output.
    Choosing "not routed" deletes an existing routing, and "cancel" aborts the routing and keeps the previous routing.

To create a routing to a MADI output on the web remote:
  1. Enter the Routing mode by pressing the corresponding icon in the title bar.

  2. Click the MADI coaxial or MADI optical output port.

  3. Select individual or consecutive channels by clicking or dragging. The channels are highlighted in blue and an arrow handler is revealed.

  4. If the input ports are closed, drag the handle onto an input port, it opens automatically.

  5. Drag the handle onto the source channel strips to select a range of channels as signal source.