Analog Line Levels

The M-32 DA Pro can be adjusted to the following reference levels:

Reference 0 dBFS Headroom at +4dBu Other RME devices

+24

+24 dBu

20 dB

-

+19

+19 dBu

15 dB

LoGain

+13

+13 dBu

9 dB

+4 dBu

When set to +24, analog outputs comply with RP 155:2014 - SMPTE Recommended Practice.

DA Converter Specifications

Line Out 1-32:
  • Resolution: 24 bit

  • Output level switchable per channel +24 dBu, +19 dBu, +13 dBu @ 0 dBFS

  • Outputs DC coupled, fully symmetrical signal path ("truly balanced")

  • Output impedance: 200 Ohm balanced, 100 Ohm unbalanced

  • Signal to Noise ratio (SNR) @ +13/+19/+24: 116 dB RMS unweighted, 119 dBA

  • Frequency response @ 44.1 kHz, -0.1 dB: 0 Hz – 22 kHz

  • THD @ -1 dBFS: < -109 dB, < 0.00035 %

  • THD+N @ -1 dBFS: < -107 dB, < 0.00043 %

  • Channel separation: > 110 dB