Power State

PSU 2 receives power

This icon in the STATE section informs the user which of the two IEC inlets receive power. It is a realtime representation of the current power state, with an inactive power supply shown in grey.

When facing the front panel, the left power plug corresponds to the left IEC inlet at the rear.

Representation of the power states on the device

  1. Open the power tab in the STATE section

    Power Tab in State section
  2. The state of each PSU is shown as active if it receives power.

Representation of the power states on the web remote

  1. Connect the device by USB or network cable and open the Remote Control Overview.

    w32 110 1C 3

  2. A click on the Power icon reveals the current state of the power supplies.

Notification of Single Power Failure

A warning can be displayed when one of two connected power sources fails.

On the display, a warning is signaled as an icon with a red bar:

wAL 110 2T 1

Power loss at PSU 2

To activate the warning on the device:
  1. Open the power tab in the STATE section.

    PSU Tab in State section
  2. Toggle the switch Redundancy to On.

The warning signals only the current state.
To activate the warning on the web remote:
  1. In the STATE section, activate the toggle next to Power Loss Warning.